| Size Range |
0.5 to 75 µm |
| Size Channels |
Factory calibrated at 0.5, 1.0, 2.5, 5.0, 10.0, 30.0 μm Variable binning – user defined channel size |
| Counting Efficiency |
50%@ 0.5 µm; 100% for particles >0. 75 µm per JIS |
| Flow rate |
0.1 CFM (2.83 LPM) |
| Concentration Limit |
15,000,000 Particles/ff’@ 10% coincidence loss |
| Battery Run Time |
>10 hours continuous operation |
| Light Source |
Long life laser diode |
| Zero Count |
<1 count / 60 minutes (<1 particles / 6 ft³). No fault count subtraction. |
| Count Modes |
Real-Time Meter and graph, cumulative/differential count/ni’ and count/ff’, and mass concentration (PM) |
| Count Alarms |
1 to 9,999,999 counts |
| Calibration |
NIST traceable |
| Display |
4.3″ (10.9 cm) WQVGA(480×272) color touch screen |
| Printer |
(Optional) External thermal printer available |
| Vacuum Source |
Internal pump with automatic flow control |
| Filtered Exhaust |
Internal HEPA filter |
| Number of Channels |
6 |
| Custom Size Channels |
Calibration for custom size channels available |
| Audible Alarm |
Adjustable built-in alarm |
| Battery |
Removable Li-ion |
| Battery Recharge Time |
4 hours within instrument (<2 hours with external battery charger) |
| Reports |
ISO 14644-1, EU GMP Annex 1, FS 209E |
| Recipes |
50 user-configurable recipes |
| Communication Modes |
Ethernet and USB. (Optional) Wireless 802.11 b/g, RS485 or RS232. |
| Environmental Sensor |
Temp and RH probe 32° to 122°F (0° to 50°C) ±1°F (0.5°C), 15-90% ±2% relative humidity |
| Alarm |
Alarms on counts for all particle sizes, sensor failure, environmental sensors and flow |
| Standards |
ISO 21501-4 and JIS B9921 |
| Instrument Calibration |
Recommended minimum once per year |
| External Surface |
Stainless steel |
| Dimensions (L x W x H) |
5.22″ x 3.81″ x 9.42″ (14.0 cmx 9.7 cmx 23.9 cm) includes barb fittings |
| Weight |
2.6 lb (1.18 kg) |
| Accessories |
Operating manual and IMS Software on USB flash drive, isokinetic probe, temperature relative humidity sensor, purge filter, battery, USB cable, power supply and cable |
| Optional Accessories |
Printed manual, temperature relative humidity sensor , isokinetic probes, barb fittings, filter, data cable, sample tubing, IMS-RT monitoring system |
| Buffer Memory |
45,000 sample records (rotating buffer) including particle count data, environmental data, locations, annotations, and times. Scrollable on screen or printout. |
| Sample Locations |
Up to 1,000 locations 20 characters long |
| Sample Time |
1 second to 99 hours |
| Power |
110 to 240 VAC 50/60 Hz universal in-line power supply |
| Operating Conditions |
41° to 104°F (5° to 40°C) /20% to 95% non-condensing |
| Storage Condition |
32° to 122°F (0° to 50°C) / Up to 98% non-condensing |
| Warranty |
2 year limited warranty. Extended warranties available. |