| Size Range |
0.3 to 25μm |
| Size Channels |
Factory calibrated at 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 μm |
| Flow rate |
0.1 CFM (2.83 LPM) |
| Counting Efficiency |
50% @ 0.3 μm; 100% for particles >0.45 μm per JIS |
| Concentration Limit |
15,000,000 Particles/ft3 @ 10% coincidence loss |
| Battery Run Time |
>10 hours continuous operation |
| Light Source |
Long life laser diode |
| Zero Count |
<1 count I 60 minutes ( <1 particles / 6 ft3) |
| Count Modes |
Automatic, manual, real-time meter, cumulative/differential, mass concentration, count or concentration |
| Count Alarms |
1 to 9,999,999 counts |
| Calibration |
NIST traceable |
| Display |
4.3″ (10.9 cm) WQVGA (480×272) color touch screen |
| Printer (Optional) |
Optional external thermal printer available. Prints in all available languages |
| Vacuum Source |
Internal pump with automatic flow control |
| Filtered Exhaust |
Internal HEPA filter |
| Number of Channels |
6 |
| Custom Size Channels |
Calibration for custom size channels available |
| Audible Alarm |
Adjustable built-in alarm |
| Battery |
Removable Li-ion |
| Battery Recharge Time |
4 hours within instrument (<2 hours with external battery charger) |
| Reports |
ISO 14644-1, EU GMP Annex 1, FS 209E |
| Communication Modes |
Ethernet and USB |
| Optional Communication Modes |
Wireless 802.11 b/g, RS485 or RS232 |
| Environmental Sensor |
Includes temperature and relative humidity probe 32º to 122ºF (0º to 50ºC) ±1ºF (0.5ºC), 15-90% ±2% relative humidity |
| Alarm |
Alarms on counts for all particle sizes, low battery, sensor failure, environmental sensors and flow |
| Standards |
ISO 21501-4 and JIS B9921 |
| Calibration |
Recommended minimum once per year |
| External Surface |
Stainless steel |
| Dimensions (L x W x H) |
5.2” x 4.15” x 8.25” (13.3 cm x 10.5 cm x 21 cm) includes barb fittings |
| Weight |
4 lb (1.8 kg) |
| Accessories |
Operating manual on USB flash drive, isokinetic probe, filter, battery, data download software, USB cable, power supply & cable |
| Optional Accessories |
Printed manual, spare battery, external battery charger, external printer, temperature and humidity sensor, and isokinetic probes |
| Buffer Memory |
45,000 sample records (rotating buffer) including particle count data, environmental data, locations and times. Scrollable on screen or printout |
| Sample Locations |
Up to 1,000 locations 20 characters long |
| Sample Time |
1 second to 99 hours |
| Power |
110 to 240 VAC 50/60 Hz universal in-line power supply |
| Operating Conditions |
41º to 104ºF (5º to 40ºC) / 20% to 95% non-condensing |
| Storage Conditions |
32º to 122ºF (0º to 50ºC) / Up to 98% non-condensing |
| Warranty |
1 year limited warranty. Extended warranties available. |